  Total Recall Owner's Manual — V2.50u PDF

      TABLE OF CONTENTS   5   INSTALLING 10  TROUBLESHOOTING TIPS
1    COMPLIANCE STATEMENT 6   GETTING STARTED 11  SPECIFICATIONS
2    INTRODUCTION 7   CONFIGURING 12  APPENDIX A, GLOSSARY
3    QUICK START-UP GUIDE 8   OPERATING 13  APPENDIX B, SCREEN MESSAGES
4    GETTING TO KNOW 9   REMOTE RECALL SOFTWARE 14  SOFTWARE LICENSE AGREMENT

       

1.     Compliance Statement

European Model

  The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point.

In the event of problems, you should contact your equipment supplier in the first instance.

This device is designed to work on any network. This device is not dependent on physical and software switch settings. If this device is to be used outside of your area or different network, contact your vendor.
This device complies with Class A of EN55022: 1995 incl. Amendments 1 & 2.

Warning

This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

 

  

New Zealand Model

This device complies with Class A of AS/NZS3548:1995, incl. Amendments 1 & 2.

Warning

This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

 

(b) “The call log incorporated in this equipment does not record all answered calls. The call log, therefore, may not agree with the Telecom account which may include calls not shown on the log.”

8.5 Recording functions.

(c) “All persons using this device for recording telephone conversations shall comply with New Zealand law. This requires that at least one party to the conversation is to be aware that it is being recorded. In addition, the Principles enumerated in the Privacy Act 1993 shall be complied with in respect to the nature of the personal information collected, the purpose for its collection, how it is used and what is disclosed to any other party.”

 

  

USA Model

FCC Rules, Part 15

Total Recall has been tested and complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, can cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s expense.

CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY Arunta Comsec Pty Ltd COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

 FCC Rules, Part 68

 1.         FCC Part 68 Registration

Total Recall complies with FCC Rules, Part 68.  On this equipment is a label that contains, among other information, the FCC Part 68 registration number. 

 2.         REN

The ringer equivalence number (REN) is used to determine the quality of devices, which may be connected to the telephone line.  Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call.  In most, but not all, areas the sum of RENs should not exceed five (5.0).  To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. 

NOTE:  RENs are associated with loop-start and ground-start ports.  It is not used for E&M and digital ports.  The REN assigned to Total Recall is 1.5B.  If requested, this information must be given to the telephone company.

 3.            Service

In the event of equipment malfunction, all repairs should be performed by Arunta Comsec Pty Ltd or an authorized agent.  It is the responsibility of users requiring service to report the need for service to Arunta Comsec Pty Ltd or to one of our authorized agents.  Service can be facilitated through our office at:

            Arunta Comsec Pty Ltd                  Omnicron Electronics

            email: total.recall@arunta.com        email: total.recall@omnicronelectronics.com

The telephone company can ask you to disconnect the equipment from the network until the problem is corrected or until you are sure that the equipment is not malfunctioning.

 4.         Facility Interface Information

In order to connect registered terminal equipment to the telephone company lines, the terminal equipment must utilize an FCC registered jack.  Standardized jacks are used for this equipment.  The following table contains Facility Interface Code (FIC), Ringer Equivalence Number (REN), Service Order Code (SOC) and network jack information for the equipment.

  

Port Identifier

FIC

REN

Network Jack

Line 1 to Line 16

Not Applicable

1.5B

RJ11C

                                 

The Total Recall interface connects to the Public Switched Telephone Network through a FCC registered NCTE that specifies the type of network jack to be used. 

5.            Disruption of the Network 

If the Total Recall disrupts the telephone network, the telephone company can discontinue your service temporarily.  If possible, the telephone company will notify you in advance.  If advance notice is not practical, they will notify you as soon as possible.  You are also informed of your right to file a complaint with the FCC. 

6.            Telephone Company Facility Changes 

The telephone company can make changes in its facilities, equipment, operations, or procedures that can affect the operation of your equipment.  If they do, you should be notified in advance so you have an opportunity to maintain uninterrupted telephone service. 

7.            Electrical Safety Advisory 

While Total Recall is fully compliant with FCC rules and regulations, it is recommended that an alternating current (AC) surge arrestor of the form and capability suitable for the model purchased be installed in the AC outlet to which the Arunta Comsec Pty Ltd products are connected.  Consult with your distributor as to the surge protector requirements for your equipment. 

Notes: a) If a ruling is required on the legality of recording in your country, please seek legal advice.
          b) This product must not be used for illegal or unauthorized recording purposes.   

Each Total Recall unit can accommodate up to 2 DSP (Digital Signal Processor) cards. The 8-channel model could have either a single 8-channel DSP card (TR-08S in table below), or two 4-channel DSP cards (special order, TR-08 in table below).  Contact your Total Recall representative for upgrade assistance.

Upgrading Total Recall to Higher Channel Capacities

The 4, 8, and 12 channel versions of Total Recall can all be upgraded to a higher channel capacity by the addition of a 4-channel (Part Number TR-U4) or 8-channel (Part Number TR-U8) DSP card. Total Recall can accommodate 2 DSP cards only so the upgrade may necessitate the prior removal of an existing DSP card(s). Possible permutations:

Current Version

Upgrade Version

Remove

Add

TR-04

TR-08

 

1 x TR-U4

TR-04

TR-08S

1 x TR-U4

1 x TR-U8

TR-04

TR-12

 

1 x TR-U8

TR-04

TR-16

1 x TR-U4

2 x TR-U8

TR-08

TR-12

1 x TR-U4

1 x TR-U8

TR-08

TR-16

2 x TR-U4

2 x TR-U8

TR-08S

TR-12

 

1 x TR-U4

TR-08S

TR-16

 

1 x TR-U8

TR-12

TR-16

1 x TR-U4