Welcome to:   OMNICRON ELECTRONICS  -  Professional Voice Logging Recorders and Accessories

    

Home

Products

Contents

Digital Recorders
Analog Recorders
Order Form
Contact Us
PDF Pages
FAQ/Q&A
Price List
Software
Services
Search
  
go directly to
Total Recall
4 to 32 channels
Total Recall MAX
8 to 92+ channels
TeleCorder
2 or 4 channels
UpCorder
2 or 4 channels/PC
   

Net-30-Day terms
to well rated firms
and Govt. agencies.

  Total Recall Owner's Manual — V4.00u PDF

TABLE OF CONTENTS 

1    COMPLIANCE STATEMENT 6   INSTALLING TOTAL RECALL 11  PREVENTATIVE MAINTENANCE
2    SAFETY INFORMATION 7   SWITCHING ON & GETTING STARTED 12  TROUBLE SHOOTING TIPS
3    INTRODUCTION 8   CONFIGURING TOTAL RECALL 13  SPECIFICATIONS
4    QUICK START-UP GUIDE 9   OPERATING TOTAL RECALL 14 & 15  APPENDIX A and B
5    GETTING TO KNOW 10   REMOTE MANAGER SOFTWARE 16  SOFTWARE LICENSE AGREEMENT

       

3.     Introduction

      Total Recall is a compact, cost-effective and self-contained digital Voice Logger/Recorder that records and provides secure storage for over 10,000 hours of calls. Call information is presented on the Liquid Crystal Display (LCD). With simple keystrokes and three easy to navigate menus, the user configures and operates Total Recall to search, playback and archive calls. Using LAN or dialup you will have remote access to Total Recall over your network or a phone line using Remote Manager.

           Available as a 4, 8, 12 or 16 channel desktop unit or 4. 8. 12, 16, 20, 24, 28, or 32 channel 19" rack mount unit, Total Recall will record the telephone numbers of incoming* and outgoing calls**, and store this information in a database, together with a time & date stamp, the duration of the call and reference to the specific channel number. All these “fields” can be used to search and retrieve calls from the database. 

           Once a call has been located and retrieved from the Total Recall database, the call can be replayed via an internal or external speaker, or, for privacy, via a headphone port.  

      *Note: Functions only if Caller ID (Caller Line Identification / CLI) is available on the line at the connection point.

     **Note:  Functions only if DTMF tones are present on the line at the connection point.

     This User Manual covers operational aspects of your Total Recall Voice Logger / Recorder operating as a stand-alone unit or as a networked device. Throughout this manual, actual screen displays are used to illustrate the operation being described. Section 3 contains a quick Start-up Guide for those users who would prefer to start in the minimum time. We recommend that you keep this manual at a location near the unit for quick reference.

           Your Total Recall supplier is available to assist you with all other technical and installation matters. 

3.1  Total Recall Models

·         TRL-04     4-channels, desktop                      TRL-16      16-channels, desktop
·        
TRR-04     4-channels, rack mount                  TRR-16      16-channels, rack mount
·        
TRL-08     8-channels, desktop                        TRR-20      20-channels, rack mount
·        
TRR-08    8-channels, rack mount                   TRR-24      24-channels, rack mount
·        
TRL-12     12-channels, desktop                   TRR-28      28-channels, rack mount
·        
TRR-12    12-channels, rack mount               TRR-32     32-channels, rack mount

     All Total Recall models are supplied with Remote Manager, the client software for Total Recall. It is a Windows based 95/98/NT/2000/ME/XP program.

     Remote Manager is used to search and replay calls from either an archive CD, if there is no requirement to use the LAN or Dial-up functionality, or enables full remote access to Total Recall via the LAN or Dial-up interface. Calls can be selected and transmitted via e-mail for replay on a multimedia PC at a remote location.

3.2   Total Recall Options

    
     3.2.1 Channel Upgrades

      Each Total Recall Desktop unit can accommodate up to 2 DSP (Digital Signal Processor) cards and the Rack Mount unit up to 4 DSP cards. Both units can be upgraded with 4 channel and/or 8 channel DSP cards. See your supplier for further information. When ordering upgrade cards, supply the model and serial number of the recorder. Ordering details:

                       
·         TR-U4                    4-channel upgrade card 
           
·         TR-U8                    8-channel upgrade card

 3.2.2        Dual Hot Swap Power Supply

              Total Recall
Rack Mount models come supplied with a standard power supply. A dual hot swap power supply is available for the rack mount models only. Contact your Total Recall supplier for details.

3.2.3    Archiving Options

                         Total Recall Desktop Models are supplied with either a CD-R Drive or CD-R/DVD+RW drive.

 3.3      Unpacking  

      Total Recall recorders distributed by Omnicron Electronics are supplied with the following items:    

     
·         Total Recall Voice Logger/Recorder (either desktop or rack mount version).
     
·         Remote Manager CD (contains PC software and documentation).
     
·         Power cable. 
     
·         Two blank CD-R and one blank DVD+RW (units with CD/DVD recorder).
     
·         Two copies of this User Manual.
      ·         Quick Start-up Guide.
     
·         A Yellow crossover cable to connect to a PC.
     
·         A Blue modem cable to connect to a serial modem.
     
·         One 18' RJ11 to RJ11 phone line input cable with “T” adapter
             for each input jack.

      The Omnicron TSA-3LM handset connection adapters or other cables may have been substituted for the phone line cables if requested when your Total Recall was ordered. Contact your Total Recall dealer if special cables or adapters are required.

      If cables have to be run, and if connection is required to the MDF or distribution frame, it is advisable to request a certified telecom engineer to install the telephone cabling required for the recorder.

 Note: DO NOT load the Remote Manager CD into the Total Recall CD drive. The Remote Manager CD is only intended for a PC.

 Important Note:     To ensure no loss of power or interruption to recordings, it is strongly recommended that Total Recall be connected to a UPS power system (Maximum power consumption for 16 channel TRL-16 is 50 Watts). Total Recall utilizes a database with potentially open and active files. Power disruption with an unclean shut down may cause damage to these files and may require a database rebuild. This rebuild will occur automatically when power returns.

 3.4      Getting Started

     
Having completed the installation of Total Recall by following the instructions in Section 6, you may commence using Total Recall immediately by following the simple instructions in the Quick Start-up Guide, Section 4.

          For a more complete understanding of the comprehensive features of Total Recall, we recommend that you read through the remainder of this manual.

 3.5      Total Recall Features

 
Total Recall
- Voice Logger/Recorder

 Total Recall Voice Logger/Recorder has the following features:    
                
                 
·         It has been specially designed to record telephone conversations,
                        or any audio signal.

·         It records digitally (records direct to a hard disk in compressed file format).

·         It starts and stops recording by VOX or Off-Hook activation.

·         It archives the recordings to DVD or CD to provide a permanent
backup record.

·         It has a high compression factor, resulting in a large storage capacity.

·         It has a facility to live monitor calls either locally or remotely.

·         All channels can be configured and managed selectively or as a group.

·         It is compact, self-contained, and easy to install and operate.

·         LAN & Dial-up connectivity is built-in.
 

Continue on to Section 4

                                               OMNICRON ELECTRONICS
                                   581 Liberty Highway,  Putnam, CT  06260

Phone:
(860) 928-0377

 Fax:
(860) 928-6477
E-mail: 
omnicron@snet.net  

  [ Top of page ] [  Home Page ] [ Table of Contents ]TRL Manual 3 ]