Total Recall Owner's Manual V4.60uR4 PDF

TABLE OF CONTENTS 

1    COMPLIANCE STATEMENT 7    SWITCHING ON & GETTING STARTED 13  TROUBLE SHOOTING TIPS
2    SAFETY INFORMATION 8    CONFIGURING TOTAL RECALL 14  SPECIFICATIONS
3    INTRODUCTION 9    OPERATING TOTAL RECALL 15  APPENDIX A
4    QUICK START-UP GUIDE 10  REMOTE MANAGER SOFTWARE 16  APPENDIX B
5    GETTING TO KNOW 11  RECORD ON DEMAND SOFTWARE 17  SOFTWARE LICENSE AGREEMENT
6    INSTALLING TOTAL RECALL 12  PREVENTATIVE MAINTENANCE             TABLE OF CONTENTS

       

1.     Compliance Statement

 European Model

       The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point.

       In the event of problems, you should contact your equipment supplier in the first instance.

       This device is designed to work on any network. This device is not dependent on physical and software switch settings. If this device is to be used outside of your area or different network, contact your vendor.

       This device complies with Class A of EN55022: 1995 incl. Amendments 1 & 2.

Warning

       This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

 New Zealand Model

       This device complies with Class A of AS/NZS3548:1995, incl. Amendments 1 & 2.

Warning

       This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

       8.1.8 Call logging (automatic set-up).

(b) “The call log incorporated in this equipment does not record all answered calls. The call log, therefore, may not agree with the Telecom account which may include calls not shown on the log.”

       8.5 Recording functions.

(c) “All persons using this device for recording telephone conversations shall comply with New Zealand law. This requires that at least one party to the conversation is to be aware that it is being recorded. In addition, the Principles enumerated in the Privacy Act 1993 shall be complied with in respect to the nature of the personal information collected, the purpose for its collection, how it is used and what is disclosed to any other party.”

 USA Model

FCC Rules, Part 15

        Total Recall has been tested and complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, can cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s expense.

 CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY COMSEC.TR Pty Ltd COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

 FCC Rules, Part 68

1.         FCC Part 68 Registration

       Total Recall complies with FCC Rules, Part 68.  On this equipment is a label that contains, among other information, the FCC Part 68 registration number. 

 2.         REN

        The ringer equivalence number (REN) is used to determine the quality of devices, which may be connected to the telephone line.  Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call.  In most, but not all, areas the sum of RENs should not exceed five (5.0).  To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. 

       NOTE:  RENs are associated with loop-start and ground-start ports.  It is not used for E&M and digital ports.  The REN assigned to Total Recall is 1.5B.  If requested, this information must be given to the telephone company.

3.         Service

        In the event of equipment malfunction, all repairs should be performed by Arunta Comsec Pty Ltd or an authorized agent.  It is the responsibility of users requiring service to report the need for service to Arunta Comsec Pty Ltd or to one of our authorized agents.  Service can be facilitated through our office at:

             COMCEC.TR Pty Ltd                        Omnicron Electronics
            Unit 5, 7 Millennium Court                 581 Liberty Highway

            Silverwater,  NSW  2128                      Putnam, CT   06260   
USA
            Australia                                               Phone: (860) 928-0377
                                                                           FAX: (860) 928-6477

            email: total.recall@totalrecallvr.com                email: service@omnicronelectronics.com

 The telephone company can ask you to disconnect the equipment from the network until the problem is corrected or until you are sure that the equipment is not malfunctioning.

4.         Facility Interface Information

        In order to connect registered terminal equipment to the telephone company lines, the terminal equipment must utilize an FCC registered jack.  Standardized jacks are used for this equipment.  The following table contains Facility Interface Code (FIC), Ringer Equivalence Number (REN), Service Order Code (SOC) and network jack information for the equipment.
 

Port Identifier

FIC

REN

Network Jack

Line 1 to Line 16

Not Applicable

1.5B

RJ11C

                                               

       The Total Recall interface connects to the Public Switched Telephone Network through a FCC registered NCTE that specifies the type of network jack to be used.

5.         Disruption to the Network

       If the Total Recall disrupts the telephone network, the telephone company can discontinue your service temporarily.  If possible, the telephone company will notify you in advance.  If advance notice is not practical, they will notify you as soon as possible.  You are also informed of your right to file a complaint with the FCC.

 6.         Telephone Company Facility Changes

        The telephone company can make changes in its facilities, equipment, operations, or procedures that can affect the operation of your equipment.  If they do, you should be notified in advance so you have an opportunity to maintain uninterrupted telephone service.

 7.         Electrical Safety Advisory

        While Total Recall is fully compliant with FCC rules and regulations, it is recommended that an alternating current (AC) surge arrestor of the form and capability suitable for the model purchased be installed in the AC outlet to which the Arunta Comsec Pty Ltd products are connected.  Consult with your distributor as to the surge protector requirements for your equipment.

 Notes:  a) If a ruling is required on the legality of recording in your country, please seek legal advice.

                  b) This product must not be used for illegal or unauthorized recording purposes.  

 2.     Safety Information

 WARNING!
 
Potential Shock Hazard

       Always follow basic safety precautions when using this product to reduce the risk of injury from fire or electrical shock.

a)      Read and understand all instructions in the user manual.

b)      Observe all warnings and instructions marked on the product.

c)      Use only a grounded electrical outlet when connecting Total Recall to a power source. If you are unsure the outlet is grounded have a qualified electrician check this.

d)      Do not touch the contacts on the ends of any of the cables used with Total Recall. If any cable becomes damaged have it repaired immediately.

e)      Shut down and unplug Total Recall from power outlets and telephone jacks prior to cleaning.

f)       Do not open Total Recall. There are no user serviceable parts inside Total Recall.

g)      Refer all servicing to qualified personnel.

 

Continue on to Section 3

                                               OMNICRON ELECTRONICS
                                   581 Liberty Highway,  Putnam, CT  06260

Phone:
(860) 928-0377

 Fax:
(860) 928-6477
E-mail: 
omnicron@snet.net  

  [ Top of page ] [  Home Page ] [ Table of Contents ]